Технические характеристики
Luminescence sensors
LUT2, LUT2
Model NameLUT2-P1116
Part No.1023500

At a glance

Small housing
Switching threshold adjustment for low fluorescence levels
Static teach-in on mark and/or background via control panel or control cable
Fast switching speed 0.5 kHz and 2 kHz

Your benefits

Its compact size enables space-saving installation
Simple setting via 2-point teach
Fast response time for high speeds
     

The product has been discontinued. Please follow the "replacement product" link for information about alternative products.

 
 

Features
Dimensions (L x W x H):22 mm x 12 mm x 40 mm
Sensing distance 1):12.5 mm
Light source 2) 3):UV-LED
Light emission:Long side
Light spot size:2 mm x 2.5 mm
Light spot direction:Vertical
Receiving filters:KV 418 (standard)
Receiving range:450 nm ... 750 nm
Adjustment:Teach-in, static
1) From front edge of lens  2) Average service life of 100,000 h at TA = +25 °C   3) Wave length: 375 nm  
Mechanics/electronics
Supply voltage Vs 1):DC 12 V ... 24 V
Ripple 2):< 5 Vpp
Power consumption 3):< 30 mA
Switching frequency 4):0.5 kHz
2 kHz, Adjustable
Response time 5):1,000 µs
250 µs
Output type:PNP: HIGH = VS- ≤ 2 V / LOW approx. 0 V
Switching mode:PNP
Output current Imax.:100 mA
Connection type:Connector M12, 4-pin
Protection class 6):II
Circuit protection:Output Q short-circuit protected
Interference suppression
VS connections reverse-polarity protected
Enclosure rating:IP 67
Weight:Ca. 11 g
Housing material:ABS
1) Limit values: DC 12 V (-10 %) ... DC 24 V (+20 %)  2) May not exceed or fall short of VS tolerances  3) Without load  4) With light/dark ratio 1:1, no time delay  5) Signal transit time with resistive load  6) Reference voltage DC 50 V  
Ambient data
Ambient temperature:Operation: -10 ... 55 °C, Storage: -25 ... 75 °C
Shock load:According to IEC 60068
UL File-No.:UL No. NRKH.E181493 & cUL No. NRKH7.E181493