FFUS20-1C1IO

FFUS20-1C1IO
Производитель: SICK
Код заказа: 6049061
Наличие: Под заказ
Срок поставки: 3-5 нед.
Количество
Цена: По запросу Оптовикам ↓
Технические характеристики
Flow sensors
Ultrasonic flowmeter
Model NameFFUS20-1C1IO
Part No.6049061

At a glance

Flow sensor for conductive and non-conductive liquids
Compact design with no moving parts
Process temperature up to 80 °C, process pressure up to 16 bar
High chemical resistance due to seal-free sensor design
Large display with membrane keyboard
Integrated teaching tube detection

Your benefits

Reduced maintenance costs
Adjustable measuring ranges reduces the number of variants
Ability to be used with conductive and non-conductive liquids reduces variants and lowers storage costs
Straight measuring tube reduces pressure loss, thus reducing energy costs
Sensor without seals increases process reliability and availability
Flexible measurement system for all industries
   
 
 
 

Features
Medium:Fluids
Nominal width measuring tube:NW 20
Process temperature:0 °C ... +80 °C
Process pressure:Max. 10 bar
Performance
Minimim flow:3.5 l/min
Maximum flow:60 l/min
Inlet zone:50 cm
Outlet zone:10 cm
Conductivity:No limitation
Accuracy of sensor element:2 % (of final value) 1)
Repeatability:≤ 0.5 %
Resolution:0.012 l/min
1) Reference condition: water, gas-free, fully-filled measuring tube, no cavitation, Medium temperature 20 °C, ambient temperature 20 °C ... 25 °C, compliance with the inlet zone and outlet zone, warm-up time electronic: 30 min  
Mechanical data
Process connection:Clamp (DIN 11864-3)
Wetted parts:PSU
Housing material:PSU
Weight:420 g
Enclosure rating:IP 67
Electrical data
Supply voltage:18 V DC ... 30 V DC 1)
Residual ripple:≤ 5 Vpp 2)
Power consumption:≤ 180 mA 3)
Initialization time:≤ 5 s
Protection class:III
Electrical connection:Round connector M12 x 1, 5-pin
Output signal:Analog output: 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature
1 pulse/status output: transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (depending on type)
4)
Impuls/frequency output:0 kHz ... 10 kHz
Puls width:≤ 1 s
Signal voltage HIGH:Vs - 2 V
Signal voltage LOW:≤ 2 V
Output current:< 100 mA 5)
Inductive load:1 H
Capacitive load:100 nF
Response time:Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s 6)
Output load:< 500 Ohm
Lower signal level:3.8 mA ... 4 mA
Upper signal level:20 mA ... 20.5 mA
1) 4) All connections are polarity protected. All outputs are overload and short-circuit protected.  2) May not exceed or fall short of VS tolerances  3) Without load  5) There are 100 mA for each output pnp and npn available.  6) Analog output and display  
Ambient data
Ambient operating temperature:0 °C ... +60 °C
Ambient storage temperature:-20 °C ... +70 °C