Продажа оборудования для промышленной автоматизации

E-mail: sale@inortek.ru
Тел: (812) 646-73-76

Курс валют ЦБ РФ
1 USD = 58.1290 руб.
1 EUR = 69.7664 руб.
на 21-09-2017
Внимание: все расчеты производятся только в безналичной форме.

S30A-6011GB

S30A-6011GB
Производитель: SICK
Код заказа: 1052108
Наличие: Под заказ
Срок поставки: 3-5 нед.
Количество
Цена: По запросу Оптовикам ↓
Технические характеристики
Safety laser scanners
S3000 Expert, Sensor head with I/O module
Model NameS30A-6011GB
Part No.1052108

At a glance

5.5 m protective field range
21 switchable field sets (21 protective fields, 42 warning fields)
Configuration memory integrated in the system plug
EFI interface for safe SICK device communication
Incremental encoder inputs for speed-dependent field switching
Extended measured data output via RS-422 with landmark recognition
Simultaneous monitoring of up to four protective fields

Your benefits

Largest protective field range in the market increases the variety of application possibilities
Variety of field sets ensures safety and productivity when protecting vehicles or moving machine parts
Expandable modular system, simple cabling and additional functions such as the simultaneous monitoring of up to four protective fields using SICK safety controllers with EFI
Quick recommissioning via configuration memory
The correct protective field at any speed avoids unnecessary stops.
Personnel protection and navigation support in one device
Easy installation, commissioning and maintenance for stationary and mobile applications
Decades of proven safety technology guarantee maximum reliability and productivity - even under difficult conditions
   

Applications
Hazardous area protection (vertical):+
Access protection (vertical):+
Hazardous area protection (horizontal):+
Functions
Number of simultaneously monitored protective fields:≤ 4 1)
Static protective field switching:+
Incremental encoder inputs:+
External device monitoring (EDM):+
Integrated configuration memory:+
Expanded measured data output (CMS, RS-422):+
Measured data output (RS-422):+
Safe SICK device communication via EFI/SDL:+
1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway.  
Technical data
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating:IP 65 (EN 60529)
Protection class:II (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-10 °C ... 50 °C
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Weight:3.3 kg
Scan angle:190 °
Protective field range:5.5 m
Maximum warning field range:49 m
Number of field sets:21 1)
Number of monitoring cases:32 2)
Response time:60 ms 3)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Distance measuring range:49 m
Number of multiple samplings:Configurable 2 ... 16
Electrical connection:System plug with or without connecting cable
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Number of EDM inputs:1
Number of reset-/restart inputs:1
Number of static control inputs:4
Number of static control inputs with EFI:5 4)
Number of dynamic control inputs:2 5)
Number of safe outputs:2, Safety outputs (OSSD)
Number of application diagnostic outputs:3 6)
Maximum output current:500 mA
Configuration and diagnostics interface:RS-232
Data interface:RS-422
1) 1 field set = 1 protective field and 2 warning fields. In dual field mode (1 protective field and 1 warning field): 32  2) In combination with an additional static input via EFI or using the dynamic inputs on the device. Otherwise 16.  3) Depending on basic response time and multiple sampling  4) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise four.  5) Two of the static swichting signals can be used either as dynamic or as static switching signals.  6) Freely programmable, e.g., warning field, contamination, reset required  

Возникли проблемы с выбором или появились вопросы - звоните (812) 646-7376 или (981) 777-7376
sale@inortek.ru
СенсорTEKOAutonicsBALLUFFifm electronic
OmronPepperl+FuchsSICKTurckBanner
Lenze-AC TechSew-EurodriveSolcon  
Copyright © ООО "Электронмаш СПб" | 197349, Россия, Санкт-Петербург, ул. Байконурская, 24 | (812) 646-7376 | sale@inortek.ru