UE403-A0930

UE403-A0930
Производитель: SICK
Код заказа: 1026287
Наличие: Под заказ
Срок поставки: 3-5 нед.
Количество
Цена: По запросу Оптовикам ↓
Технические характеристики
Switching amplifiers
Safety switching amplifier
Model NameUE403-A0930
Part No.1026287
     

Functions
Muting (with M4000 Advanced, M4000 A/P):+
Concurrence monitoring (with M4000 Advanced, A/P):+
Override (with M4000 Advanced, A/P):+
Monitoring total muting time (with M4000 Advanced, A/P):+
Sensor gap monitoring (with M4000 Advanced, A/P):+
Sensor test (with M4000 Advanced, A/P):+
Partial blanking (with M4000 Advanced, A/P):+
End of muting by ESPE (with M4000 Advanced, A/P):+
Belt stop (with M4000 Advanced, A/P):+
Number of muting sensors:4
Connection muting lamp:+
Connection belt stop signal:+
Connection additional signal C1:+
Connection reset control switch:+
Connection override control switch:+
Technical data
Protection class:III (EN 50178:1998)
Enclosure rating:IP 65 (IEC 60529)
Safety integrity level:SIL3 (IEC 61508), SILCL3 (IEC 62061)
Category:Category 4 (EN ISO 13849)
Performance level:PL e (EN ISO 13849)
PFHd:1.0 * 1E-08
TM (mission time):18 a
Dimensions (W x H x D):76.5 mm x 225.2 mm x 40 mm
Supply voltage from, typical, to:19.2 V DC, 24 V DC, 28.8 V DC
Maximum power consumption:2
Type of muting sensors:inductive sensors, mechanical switches, Optical sensors, controller signals
Electrical connection:Socket M12 x 5
Switching voltage HIGH inputs from, typical, to:11 V DC, 24 V DC, 30 V DC
Input current HIGH from, typical, to:6 mA, 10 mA, 15 mA
Switching voltage LOW inputs from, typical, to:-30 V DC, 0 V DC, 5 V DC
Input current LOW from, typical, to:-0.5 mA, 0 mA, 1.5 mA
Supply voltage outputs from, typical, to:15 V DC, 24 V DC, 28.8 V DC
Supply current outputs for muting sensors:400 mA
Supply current outputs for reset, override or C1:500 mA
Switching voltage HIGH output, muting lamp, from, typical, t:15 V DC, 24 V DC, 28.8 V DC
Output current HIGH (monitored), muting lamp, from, to:Monitored, 20 mA, 400 mA
Output current HIGH (not monitored), muting lamp, from, to:Not monitored, 0 mA, 400 mA
Maximum output power HIGH, muting lamp:5 W
Maximum cable length to ESPE:10 m
Minimum conductor cross-section:0.34 mm?
Wire cross section from ... to:0.34 mm?
Maximum cable resistance:< 0.5 Ω (per cable)
Ambient operating temperature from ... to:-10 °C ... 55 °C
Storage temperature from ... to:-25 °C ... 70 °C
Air humidity from ... to: 15 % ... 95 %, non-condensing
Vibration resistance (checked to):5 (IEC 60068-2-6)
Oscillation frequency from ... to:10 ... 55
Shock resistance:10 g, 16 ms (IEC 60068-2-29)
Housing material:Die-cast aluminum (powder coated)
Material, connector strip:Polyamide
Mounting:flexible mounting to the M4000 Advanced or directly in the system
System part:Safety relays